- MFD.BY:Fincantieri, Italy
- DATE MFD:1990
- TYPE:Steam Turbine.
- RATED-HP:15282
- TURBINE-TYPE:Condensing
- No.STAGES:11
- EXTRACTION:NA
- INLET STEAM:540.8# @ 626Deg F. [8" 600# RH] [Casing inlet zone rated OP 40bar/588# @ 400degC, DP 71bar/1043#]
- EXHAUST STEAM:3.5"Hg
- GOVERNOR:Woodward 505, 3993 rpm. MCOS 6680trip, O/S trip 7348RPM.
- ROTATION:CW looking from the governor end, output shaft facing away.
- HOURS:UNUSED since major overhaul 2004. Disassembled, all components coated in preservative. Rotating element stored in heated warehouse.
- PRIOR SERVICE:11.5MW Generator driver.
- COMMENTS:Turbine & reducer w/clutch on common baseplate w/shaft driven primary lube oil system, Allweiler SNFDA 440 and Electric driven Aux. oil pump w/piping & [2] 43.1Sq.M. shell & tube lube oil coolers & Lube oil purifier/filter, Murisenco duplex w/4"in/out, ca
- SHIPPING SIZE-W X H X L:13'10W X 12'7"H X 23'L
- APPROX. WEIGHT-LBS:80000#
- QUANTITY:1